Certified Data Centre Professional

Certified Data Centre Professional

Summary

Location

Location

Malaysia

Duration

Duration

2 Days
Format

Format

Public Class

Public Class

Become a Certified Data Centre Professional (CDCP®)

Are you ready to elevate your career in the world of data centers? Look no further than our Certified Data Centre Professional (CDCP®) course. In just 2 days of engaging and interactive training, you can unlock a world of opportunities in the data center industry.

What You'll Learn

Our CDCP® course is designed to equip you with the knowledge and skills to excel in data center management. From understanding the critical components of data centers to setting up and maintaining high-availability facilities, this course covers it all. You’ll dive into industry standards, power infrastructure, cooling techniques, network architecture, fire protection, and more. By the end of this course, you’ll be well-prepared to make mission-critical decisions, ensuring the reliability and security of data centers.

Your Career Journey

Whether you’re a seasoned professional or just starting out, this course is open to all. If you’re already in the field, CDCP® will enhance your expertise. And if you’re new to data centers, don’t worry – you’re welcome to join too. With a CDCP® certification in hand, you’ll stand out in a competitive job market and have the skills to make a real impact in the data center industry. Ready to embark on this journey? Become a Certified Data Centre Professional today!

Course Details

Course Code: CDCP; Duration: 2 Days; Instructor-led

The CDCP® (Certified Data Centre Professional) is a 2-day course is designed to expose participants to the key components of the data centre. CDCP® training will address how to setup and improve key aspects such as power, cooling, security, cabling, safety etc. to ensure a high-available data centre. CDCP® training will also address key operations and maintenance aspects.  

CDCP® is the first training in the EPI Design and Build training track under the EPI Data Centre Training Framework.

Audience

The primary audience for the CDCP® course is an IT, Facilities or Data Centre Operations professional working in and around the data centre (representing both end-customers and/or service provider/facilitators) and having responsibility to achieve and improve hi-availability and manageability of the Data Centre, such as: Data centre managers, Operations / Floor / Facility managers, data centre engineers, network/system engineers/data centre sales/consultants.

Prerequisites

There is no specific prerequisite for the CDCP® course. However, participants who already have at least one- or two-years’ experience in a data centre or facilities environment may be best suited. Those with no experience just yet are most welcome to participate.

Methodology

This program will be conducted with interactive lectures, PowerPoint presentations, discussions and practical exercises

Course Objectives

After completion of the course the participant will be able to:

  • Choose an optimum site for mission-critical data centre based on current and future needs
  • Describe all components that are important for high availability in a data centre and how to effectively setup the data centre
  • Name and apply the various industry standards
  • Describe the various technologies for UPS, fire suppression, cooling, monitoring systems, cabling standards, etc, and to select and apply them effectively to cost-efficiently enhance the high-availability of the data centre.
  • Review the electrical distribution system to avoid costly downtime
  • Enhance cooling capabilities and efficiency in the data centre by using existing and new techniques and technologies for the increased cooling requirements of the future
  • Design a highly reliable and scalable network architecture and learn how to ensure installers apply proper testing techniques
  • Describe (high-level) data centre operational considerations supporting mission-critical environments
  • Setup effective data centre monitoring ensuring the right people get the right message
  • Ensure proper security measures, both procedural and technical, are established to safeguard your company’s valuable information in the data centre

Outlines

  • Data Centre Standards and Best Practices
  • Data Centre Location, Building and Construction
    • Selecting appropriate sites and buildings and how to avoid pitfalls
    • Various components of an effective data centre and supporting facilities setup
  • Uniform, concentrated and rolling load definitions
  • Applicable standards
  • Raised Floor guidelines
  • Signal Reference Grid, grounding of racks
  • Disability act and regulations
  • Suspended ceiling usage and requirements
  • Standards
  • Light fixture types and placement
  • Emergency lighting, Emergency Power Supply (EPS)
  • Power infrastructure layout from generation to rack level
  • ATS and STS systems
  • Redundancy levels and techniques
  • Three-phase and single-phase usage
  • Power distribution options within the computer room 
  • Power cabling versus bus bar trunking
  • Bonding versus grounding
  • Common Mode Noise and isolation transformers
  • Distribution boards, form factors and IP-protection grades
  • Power quality guidelines
  • Real power versus apparent power
  •  How to size and calculate load in the data centre
  •  Generators
  • Static and dynamic UPS systems, selection criteria, how they operate and energy efficiency option
  •  Battery types, correct selection and testing
  •  Thermo-graphics
  • Electrical fields and magnetic fields definitions and units of measurements
  • Sources of EMF
  • Effects of EMF on human health and equipment
  • (H)EMP
  • Standards
  • EMF shielding solutions
  • Rack standards, properties and selection criteria
  •  Security considerations
  • Power rail/strip options
  • Temperature and humidity recommendations
  •  Cooling measurement units and conversion rates
  •  Sensible and latent heat definitions
  • Differences between comfort and precision cooling
  • Overview of different air conditioner technologies
  • Raised floor versus non-raised floor cooling
  • Placement of air conditioner units and limitations to
  • Be observed
  •  Supplemental cooling options
  • Cold aisle/hot aisle containment
  • Importance of water supply and application areas
  • Backup water supply techniques
  • The importance of a Structured Cabling System
  • Planning considerations
  • Copper and Fiber cable technology and standards
  •  ANSI/TIA-942 Cabling hierarchy and recommendations
  • Testing and verification
  •  SAN storage cabling
  • Network redundancy
  •  Building-to-building connectivity
  • Network monitoring system requirements
  • Standards for fire suppression
  • Detection systems
  • Various total flooding fire suppression techniques and systems, their benefits and disadvantages
  • Handheld extinguishers
  • Signage and safety
  • Regulatory requirements and best practices
  • Physical security considerations
  • Physical safety considerations
  • Data centre monitoring requirements
  • EMS, BMS and DCIM
  • Water leak detection systems
  • Alarm notification
  • Data centre security layers
  • Service Level Management
  • Organisation
  • Safety
  • Security
  • Facilities maintenance
  • Monitoring
  • Governance

Trainers

Reviews

Interested In

Certified Data Centre Professional

Starting From
RM3550
Intake Date
5-6 AUG 2024
,
23-24 SEPT 2024
Class Type
Private, Public

Why Us

Variety of Courses

Variety of Courses

Customizable Class

Customizable Class

Consultants Facilitate

Consultants Facilitate

HRDF Claimable

HRDF Claimable

Professional Certifications

Professional Certifications

Free Chat to Get Quote

Free Chat to Get Quote

Related Courses

Enquire Now

Course Name *
Name *
Email *
Contact No. *
Enquiry For
Company Name *
Job Position *
Message *

Book Now

Course Name: Certified Data Centre Professional
Duration: 2 Days
Class Type *
Intake Date *
First Name *
Last Name *
Email *
Contact No. *
Pax *
Total Price: RM
0.00

Download Details

Name *
Email *
Contact No. *