CDFOM - Certified Data Centre Facilities Operations Manager | IT Training & Certification | Info Trek
Respect Your Dreams
Follow through on your goals with courses

CDFOM - Certified Data Centre Facilities Operations Manager

  • Private Class Icon
    Private Class
    • All of our private classes are customized to your organization's needs.

      Click on the button below to send us your details and you will be contacted shortly.
    3 Days

Course Details

Expand All

Managing the facilities of today’s hi-end and hi-availability data centres is an extremely demanding and complex task which is often under estimated. There is often very little appreciation and understanding of the complexities of managing today's mission critical data centres, especially since many of the data centres are operating at, or near, their design limits and downtime is never an option. The way a data centre is managed at the facilities layer makes all the difference. Even a data centre designed to Tier-4 as per the ANSI/TIA-942 standard could still experience many unscheduled down time events due to poor planning, operations, maintenance and management processes.


The CDFOM® course is a 3 day course which will enable participants to gain in-depth knowledge in managing data centre operations which include the following key subject matters; capacity planning, latest green initiatives, how to properly commission and de-commission equipment, compliance to safety standards, statutory compliance and international standards, managing people, vendor management, handling incident/crisis management as well how to keep operations really simple, manageable, effective and efficient and much more.

The primary audience for this course is an IT, facilities or Data Centre Operations professional working in and around the data centre and having oversight accountability or responsibility for achieving and improving high availability and manageability of the data centre operations.

It is advisable for the participants to have some experience in data centre operations although it is not required. Highly recommended is to attend the CDCP® prior to attending CDFOM®.

This program will be conducted with interactive lectures, PowerPoint presentations, discussions and practical exercises

After completing this course, you will be able to:

• To setup a data centre facilities operations team

• To manage and motivate your facilities management team

• To setup SLA’s and manage them including liabilities, KPI’s etc.

• To manage vendors and measure their performance

• To manage physical security taking into account requirements of standards such as ANSI/TIA-942 etc.

• To manage safety & statutory requirements

• To effectively and efficiently manage data centre operations

• To manage documents

• To set-up equipment life cycle including testing

• To define data centre design limits and set-up and manage a proper capacity management plan

• To commission and de-commission equipment

• To go about IT cable management

• To manage the day-to-day data centre operations


Modules

Expand All

• Criteria and attributes to leadership

• How to set-up up an efficient and effective facility management operations team structure
• Defining roles, responsibilities and skill metrics
• Key Performance Objectives (KPO) and appraisals
• Job rotation, reward, promotion and succession planning as strategies to grow and retain talent
• Training and assessments
• Shift management, scheduling and roster planning

• Vendor selection and qualification Managing risk and dealing with non-compliance, public liability, legal, escalation and complaint procedures

• Key considerations of a vendor agreement for services

• Performance measurement and reporting


• Maintenance options

• Main considerations for maintenance agreements

• The practicality in deciding between comprehensive/non-comprehensive maintenance regimes

• Warranty pit falls

• Service reports alignments with maintenance agreements


• Statutory and industry compliance/regulations

• Emergency response and safety policies and procedures

• PTW (Permit To Work) requirements and procedures

• General rules and regulations for the Data Centre

• Ergonomic workspace

• SOP’s for power outage, fire, bomb threat etc.


• Defining the Data Centre design limitations

• Defining measurement criteria and reporting

• Alignment of business SLA with vendor SLA

• Defining chance management procedure for installation and de-installation of new equipment

• Reporting and escalation management


• Guidelines from standards; ANSI/TIA-942, ISO/IEC- 27001/02, SS507, ISO/IEC-24762

• SOP (Standard Operating Procedures) in managing day to day security access control, such as;

• Entry/exit control and access management

• Permit-To-Work (PTW) and contractor work in progress

• Delivery of goods

• Customer access

• Etc.

• Effective patrols routing and how to ensure 24x7 vigilance

• Handling external threats; crisis/emergency situations

• Security incident management


• ITSM/ITIL (IT service management) in the Data Centre

• Shift hand-over requirements and procedures

• Asset and inventory management for hardware, software, spares, consumables, etc.

• Floor management procedures and duties such as rack space allocations, management of installers


• SOP of managing A&A /_t-out work-in-progress

• Pre-installation analysis for power, cooling, weight, EMF, fire protection and other influencing factors

• From truck to rack

• Handling of incoming equipment

• Inspection, unpacking and security procedures

• Staging procedure and requirements

• Equipment movement into the computer room

• Finishing up the installation

• De-installation/commissioning procedures


• Defining the design limits of the Data Centre

• Setting up thresholds, monitoring and reporting

• Business review and future capacity planning

• Technical solutions aiding capacity planning such as Computational Fluid Dynamics (CFD), capacity and configuration management solutions


• Overview of ANSI/TIA-942, ANSI/TIA-606 requirements

• Cabling specification & labelling based on ANSI/TIA-606

• In-rack power and network cabling

• Labelling requirements

• Cabling/cable tray layout documentation


• Types of pollution found in Data Centres such as H2S, air-particulates etc.

• Common causes of pollution in the Data Centre

• Standards, policies and techniques to reduce and cleanup dust, pests and other pollution and disturbances


• Tiered maintenance considerations

• Preventive, Predictive, Condition and Reliability Centred (RCM) based maintenance

• Requirements of a comprehensive maintenance program including descriptions on what should be tested for which type of equipment such as generator, UPS etc.

• The importance and actions for predictive maintenance; thermo-scan, pumps vibration and alignment test, BMS failure and system back-up testing, generator load testing etc.

• Annual testing for main equipment like transformer, genset, HT gear, chiller, cooling tower etc;

• Managing on-site /off-sites spares and how to determine which spares to keep on-site

• Daily maintenance routines such as data logging, daily checks, daily measurements, reporting and analysis etc.


• Data Centre monitoring requirements

• Threshold setting and reporting requirements

• Notification and escalation requirements

• Automated 24hrs helpdesk ticketing systems

• Incident and customer complaint management & change management

• Performance measurement and monitoring requirements such as fuel and water consumption, PUE/DCiE etc.


• Document management standards

• Document management process requirements

• Minimum and desired design documentation set

• Operational management documents


• Policies and procedures governing life cycle management

• Asset management including software and firmware

• Service situations

• Review, triggers and reporting

• Test life cycle


Trainers

Reviews

0
based on 0 ratings reviews